| LogDator™ 2" under-water logger specifications
| |
| Model item number | LD-02-00 |
| Physical | |
| Dimensions | 190 mm x 51 mm (excluding finger screw and optional sensors) |
| Mass | 0.45 kg (1 lb.) |
| Buoyancy in sea water | Nearly neutral |
| Depth rating | 45 m (150') - higher on request |
| Sensors | |
| Built-in channels | Temperature (cK, ±0.3 K), battery voltage (mV, ±0.1 V) |
| Optional sensors | 2 channels with signal conditioning (e.g., light, pressure) |
| Direct input channels | 6, one of which can be used for temperature (no software support for the others) |
| Logger | |
| Model | LogDator™ LM-01-00/D |
| A/D converter | 12-bit resolution in hardware, 16-bit after anti-aliasing |
| Optional sensor sampling | Bursts of 0 to 84 samples at 0.5 Hz to 50 Hz |
| Measurement interval | User selectable from 1 second to 24 hours |
| Real-time clock | UTC (GMT) by default, can be set to within 0.02 s |
| Data records | 512-byte records that include metadata and 16-bit analog data |
| Analog data | Stored as voltage, not in physical units (with the exception of temperature) |
| Conversion and calibration | Performed in software, see below |
| Internal memory | 2 MB (4096 records) |
| Memory cards | SD and MMC cards up to 2 GB |
| User interface | NavPin control stick and 2 x 8 char LCD display |
| Diver interface | Magnetic switch for mode change |
| Computer interface | USB and RS-485 (EIA-485, TIA-485) |
| Network | Up to 255 units per RS-485 cable |
| Network protocol | LogDator Communication Protocol ver. 1.0 |
| Power supply options | 2 size AA Li batteries 2.1 Ah, RS-485 cable, USB |
| Power backup | Keeps settings for several minutes without power connected, if in idle |
| Power demand | |
| Input voltage range | 3.5 V < Usupply < 9 V for most sensors, 5.5 V < Usupply < 9 V for 5 V sensors |
| Minimum RAM retention voltage | 1.8 V (lower voltages lead to a Reset) |
| Current use in idle, no card | 0.83 mA in RS485 mode; 32 μA in Log or Sleep mode |
| Current use of memory card | MMC and SD cards typically use 0.1 mA to 0.25 mA in idle |
| Current drain from supply | Ipeak < 5 mA, Iaverage < 1 mA |
| Multiple power sources at once | The one with the highest voltage is used (battery, USB, or RS-485 cable) |
| Software "sedimeter.exe" | |
| Functions | Set-up, download, real-time monitoring, data analysis, data export, edit calibrations, etc. |
| Optional data analysis | Average, frequency, and amplitude measure of burst samples from one measurement |
| Communication methods | USB and RS-485 (EIA-485, TIA-485) |
| Simultaneous capacity | 255 instruments via RS-485, 1 via USB |
| File import | .ld2 files written by the LogDator™ on memory cards |
| Conversion to physical units | Selectable equation for optional sensors |
| Conversion coefficients | User-editable calibration file allows any number of calibration sets per instrument |
| Network definition file | Lists the instruments to be monitored, and optionally their coordinates, in plain text |
| Functions, logging | Instrument setup; data download, presentation, analysis, export |
| Functions, real-time | Control 1 to 255 networked SediMeters; data presentation locally and on web server |